International Journal of Management and Applied Science (IJMAS)
.
Follow Us On :
current issues
Volume-10,Issue-1  ( Jan, 2024 )
Past issues
  1. Volume-10,Issue-1  ( Jan, 2024 )
  2. Volume-9,Issue-12  ( Dec, 2023 )
  3. Volume-9,Issue-11  ( Nov, 2023 )
  4. Volume-9,Issue-10  ( Oct, 2023 )
  5. Volume-9,Issue-9  ( Sep, 2023 )
  6. Volume-9,Issue-8  ( Aug, 2023 )
  7. Volume-9,Issue-7  ( Jul, 2023 )
  8. Volume-9,Issue-6  ( Jun, 2023 )
  9. Volume-9,Issue-5  ( May, 2023 )
  10. Volume-9,Issue-4  ( Apr, 2023 )

Statistics report
Apr. 2024
Submitted Papers : 80
Accepted Papers : 10
Rejected Papers : 70
Acc. Perc : 12%
Issue Published : 119
Paper Published : 5065
No. of Authors : 10504
  Journal Paper


Paper Title :
A Case Study on the Limitation of Reference Band Pass Filter for an NDIR Gas Analyzer

Author :Trieu-Vuong Dinh, Ji-Won Ahn, In-Young Choi, Dong-June Kim, Yoo-Jin Jung, In-Young Kim, Shin-Young Park, Meeli Ju, Jo-Chun Kim

Article Citation :Trieu-Vuong Dinh ,Ji-Won Ahn ,In-Young Choi ,Dong-June Kim ,Yoo-Jin Jung ,In-Young Kim ,Shin-Young Park ,Meeli Ju ,Jo-Chun Kim , (2018 ) " A Case Study on the Limitation of Reference Band Pass Filter for an NDIR Gas Analyzer " , International Journal of Management and Applied Science (IJMAS) , pp. 18-20, Volume-4,Issue-12

Abstract : The effect of a reference band pass filter (BPF) on the output signal of a non-dispersive infrared (NDIR) analyzer was investigated in this study. The BPF wavelength was 3.95 m with a half band width of 90 nm. The frequency of the filter wheel was 10 Hz and the optical pathlength was 10 m with Aluminum-coated mirrors. The IR source power was 20W. A pyro electric detector was used to detect the variation of IR intensity. Zero gas, CO, NO, NO2, SO2, CO2, humid air (H2O) and Toluene were respectively introduced into the gas chamber. It was found that there was a statistically significant difference at the 95.0% confidence level between the means of the detector signal associated with CO2, SO2, Toluene, H2O and those of zero gas. It indicated that the output signal related to the reference BPF was not stable and consistent. Therefore, it seems to be the bias of analytical results occurred. Hence, other reference methods need to be applied. Index Terms - Reference band pass filter, NDIR, Interference, Gas analyzer, Mid-IR.

Type : Research paper

Published : Volume-4,Issue-12


DOIONLINE NO - IJMAS-IRAJ-DOIONLINE-14595   View Here

Copyright: © Institute of Research and Journals

| PDF |
Viewed - 45
| Published on 2019-03-05
   
   