International Journal of Mechanical and Production Engineering (IJMPE)
.
Follow Us On :
current issues
Volume-12,Issue-1  ( Jan, 2024 )
Past issues
  1. Volume-11,Issue-12  ( Dec, 2023 )
  2. Volume-11,Issue-11  ( Nov, 2023 )
  3. Volume-11,Issue-10  ( Oct, 2023 )
  4. Volume-11,Issue-9  ( Sep, 2023 )
  5. Volume-11,Issue-8  ( Aug, 2023 )
  6. Volume-11,Issue-7  ( Jul, 2023 )
  7. Volume-11,Issue-6  ( Jun, 2023 )
  8. Volume-11,Issue-5  ( May, 2023 )
  9. Volume-11,Issue-4  ( Apr, 2023 )
  10. Volume-11,Issue-3  ( Mar, 2023 )

Statistics report
Apr. 2024
Submitted Papers : 80
Accepted Papers : 10
Rejected Papers : 70
Acc. Perc : 12%
Issue Published : 130
Paper Published : 2388
No. of Authors : 6802
  Journal Paper


Paper Title :
Realization of an Accurate Glycosuria Sensor using Silicon based 1D (One Dimensional) Photonic Structure

Author :M.K.Sahoo, G.Palai, D.Patanaik, C.S.Mishra

Article Citation :M.K.Sahoo ,G.Palai ,D.Patanaik ,C.S.Mishra , (2022 ) " Realization of an Accurate Glycosuria Sensor using Silicon based 1D (One Dimensional) Photonic Structure " , International Journal of Mechanical and Production Engineering (IJMPE) , pp. 16-20, Volume-10,Issue-12

Abstract : Silicon based 1D (one dimensional) photonic crystal structure is disclosed in the research to detect the amount of glucose in the urea at the signal of 1550 nm. The deviation of both electric and magnetic field is employed by FDTD(finite difference time domain) method. The proposed structure is realised through 3 layers where first and third layer is taken of silicon and middle layer contains the sample. The output result infers that both electric and magnetic field is found zero for normal urea but these electric and magnetic field is differed from different concentrations of biological liquid material glucose in urea. For example; electric fields are 0 V/m, 0.4567 V/m, 0.4525 V/m, 0.4483 V/m, 0.4398 V/m, and 0.4313 V/m and magnetic(TM) fields are 0 Amp/m, 0.423 Amp/m, 0.4187 Amp/m, 0.4143 Amp/m, 0.4056 Amp/m, and 0.3969 Amp/m with respect to the glucose concentrations 0 to 0.15 gm/dL, 0.625 gm/dL, 1.25 gm/dL, 2.5 gm/dL, 5.0 gm/dL, and 10 gm/dL. Finally, it is concluded that the status of urea whether it contains glucose or area fetched by knowing the electric field and magnetic field at output end. Keywords - 1D Photonic Structure; Glucose-Urea Sensor; FDTD; Electric and Magnetic Field

Type : Research paper

Published : Volume-10,Issue-12


DOIONLINE NO - IJMPE-IRAJ-DOIONLINE-19671   View Here

Copyright: © Institute of Research and Journals

| PDF |
Viewed - 18
| Published on 2023-07-13
   
   
IRAJ Other Journals
IJMPE updates
Volume-12,Issue-1 (Jan, 2024 )
The Conference World

JOURNAL SUPPORTED BY