International Journal of Electrical, Electronics and Data Communication (IJEEDC)
eISSN:2320-2084 , pISSN:2321-2950
.
Follow Us On :
current issue
Volume-12,Issue-1  ( Jan, 2024 )
ARCHIVES
  1. Volume-11,Issue-12  ( Dec, 2023 )
  2. Volume-11,Issue-11  ( Nov, 2023 )
  3. Volume-11,Issue-10  ( Oct, 2023 )

Statistics report
Apr. 2024
Submitted Papers : 80
Accepted Papers : 10
Rejected Papers : 70
Acc. Perc : 12%
Issue Published : 133
Paper Published : 1712
No. of Authors : 4737
  Journal Paper


Paper Title :
ECG Monitoring Of A Cardiac Patient Using Embedded System

Author :Sai Bipin Palakollu, J. Prithvi, M. R. Manoj, Sree Teja, Sai Kumar, M.Ganesan.

Article Citation :Sai Bipin Palakollu ,J. Prithvi ,M. R. Manoj ,Sree Teja ,Sai Kumar ,M.Ganesan. , (2014 ) " ECG Monitoring Of A Cardiac Patient Using Embedded System " , International Journal of Electrical, Electronics and Data Communication (IJEEDC) , pp. 35-40, Volume-2,Issue-7

Abstract : This paper presents a novel method to alert a cardiac patient using an embedded system. This system is chosen, based on factors such as processing speed and portability, to reliably monitor the ECG signal of the patient. Based on minimum processing time required and compatibility with the processor, an algorithm has been selected for processing of the ECG signal. Since QRS complexes are predominant in the ECG signal, the algorithm is used to detect the same. Using first order differentiation, Hilbert transform of the signal, and adaptive thresholding, the algorithm detectsQRS complexes in the signal. Further, onapplying a second threshold on the detected QRS complex, R peaks are located accurately. When an abnormal ECG signal is detected, the chosen processor Raspberry piis interfaced with a buzzer which generates an alert. The algorithm provides diminished P and T peaks, amplifies QRS peaks, and in addition motion artifacts and noise are greatly reduced. The algorithm is validated on a set often 10s recordings which are taken from MIT/ BIH Arrhythmia database. The results are compared with the corresponding annotations of database, a sensitivity of 97.73% and a detection error rate of 4.52% was obtained.

Type : Research paper

Published : Volume-2,Issue-7


DOIONLINE NO - IJEEDC-IRAJ-DOIONLINE-961   View Here

Copyright: © Institute of Research and Journals

| PDF |
Viewed - 69
| Published on 2014-07-01
   
   
IRAJ Other Journals
IJEEDC updates
Volume-12,Issue-1(Jan ,2024) Want to join us ? CLick here http://ijeedc.iraj.in/join_editorial_board.php
The Conference World

JOURNAL SUPPORTED BY

ADDRESS

Technical Editor, IJEEDC
Department of Journal and Publication
Plot no. 30, Dharma Vihar,
Khandagiri, Bhubaneswar, Odisha, India, 751030
Mob/Whatsapp: +91-9040435740